PENDANT STATIONS
GIOVENZANA company leader of industrial handling system components;
according to international regulations, have realized new pendant
stations series P02 - P03 - PL - PLB.
These new series are the result after the long investigation custom's
operations on:
- suitable space for easy wiring
- possibility to operate with a light pendant station with easy
handling
- assembling versatile in all versions which allows a fast interchange
ability of new operators Ø 22mm and their Pegasus contact
blocks
- each pendant station, fits an emergency mushroom of new generation
according
- to EN 418 regulations, equipped of snap opening action,
which does not allow the button the Stop function activated before
to be in lock position "Positive opening"

The contact blocks standard are:
- 1 NO for movement (FEM 9.941)
- 1 NC for emergency (EN 418)
- 2 NO reset / alarm
all accessories are always furnished separately and assembled
from the customer
MANUFACTURSR'S DECLARATION
As defined by EC Machinery directive CE89/392 annex IIB
GIOVENZANA
here is declared that the construction of P02 - P03 - PL - PLB series
complies with the following directives:
Applied harmonized standard
- EN 292 part 1 and 2 (safety of machines)
- EN 29001/ISO 9001 (quality assurance records)
- EN 60529 (IP..classes protection degrees)
Applied standards and technical specifications
- IEC 947-5-1 (low voltage switchgear)
- FEM 9.941 (symbols for control apparatus)
As stipulated by annex V of EC machinery direct Technical documentation
filed in manufacturer's works
SPECIFICATIONS
- double insulating enclosure in self-extinguish material
- IP65 protection degree as EN60529
- operating temperature -25o +70oC as IEC 68-2-27
- storage temperature -40o + 70oC
- availability from 2 to 14 holes, Ø22mm at single row
and double row
- cable: P03 cable sleeve from Ø 8 to Ø 17mm
- cable: PL, PLB cable sleeve Ø 8 to Ø 24mm
- emergency safety mushroom as EN60204-1-EN 418
- mechanical life: 1 million operations
- polypropylene P02-PTRM
CONTACT BLOCKS TECHNICAL CHARACTERISTICS
- no flame materials: VO
- electrical rating: 16A (4) 380V. as CEI -EN 60947-5-1
- insulating voltage: 600V. as IEC 947-5-1
- insulating category: C group as VDE 0110
- contact resistance:
25 m 
- contact block with double gap self-cleaning
at slow make contact NC "Positive opening" 
- operating strength: 4 N
- terminal protection degree: IP20 EN 60529
- contact blocks per operator max. 3
- approved UL A600 Q600
|